• CONSULTAR

USBXI-1070B

0 €
0,00 € IVA INCLUIDO

Simultaneous synchronization between modules.
Easy to set up local/wide area network by WIFI/Lan. USB/LAN/WIFI/RGB, and mouse keyboard supported.
The chassis supports the following USB modular products: Oscilloscope, Multimeters, Logic Analyzers, DC Power Supply, Arb. Waveform Generator, Frequency Counter, Field strength meter...

Cantidad
CONSULTAR

USBXI-1070B

CHASIS PARA EQUIPOS COMPATIBLES CON USBXI

Standard USBXI TM interface, easily inserts into USBXI TM housing to make up a combination instrument.

I. Features & Specifications

  • Simultaneous synchronization between modules.
  • High-speed USB 2.0, Hot-swappable and auto-detectable characteristic minimizes startup time/effort
  • Win XP/ Win 7 Microsoft? Windows? operating system, touch screen, easy to second development.
  • Easy to set up local/wide area network by WIFI/Lan.
  • USB/LAN/WIFI/RGB, and mouse keyboard supported.
  • The chassis supports the following USB modular products: Oscilloscope, Multimeters, Logic Analyzers, DC Power Supply, Arb. Waveform Generator, Frequency Counter, Field strength meter...
  • USBXI-1070A: Computer inside with touch screen.
  • USBXI-1070B: Computer inside, no screen.
  • USBXI-1070C: No computer inside.

II. Optional Module:

Power Supply Oscilloscope Arb. Waveform Generator Logic Analyzer Data Logger
Hantek1004A Hantek6022BE Hantek1025G Hantek4032L Hantek365A
Hantek6052BE Hantek365B
Hantek6082BE Hantek365C
Hantek6102BE Hantek365D
Hantek6202BE

III. Standard Modules

Model USBXI-1070B USBXI-1070C
Computer Inside Yes No
Touch Screen No No
WIFI/LAN Yes No


IV. Main Modules Specificaions

i. Programmable Power Supply Hantek1004A

a. Voltage feature

1) Low ripple and low noise;
2) Support high accuracy and dynamic programme output;
3) Fast automated test software programming;
4) Automatic data storage function;
5) Software calibration function and standard instrument board design;
6) Support USB2.0 communication;
7) Support UXI protocol;
8) Input voltage range: DC +12~18V;
9) Be able to arbitrarily work with other instruments.

b. Voltage source specification:

1) Nominal voltage output:

A) Channel 1: DC -5V, 300mA Max;

B) Channel 2: DC +5V, 2000mA Max;

C) Channel 3: DC 0~9V voltage floating output, 2000mA Max;

D) Channel 4: DC 0~9V voltage floating output, 2000mA Max;

2) Setup voltage resolution: DC 10mV;

3) Readback voltage resolution: DC 10mV;

4) Setup voltage accuracy: 0.1%;

5) Readback voltage accuracy: 0.1%;

6) Ripple: 2.5mVp-p.

c. Software:

1) Excellent industrial design, the similar interface to benchtop oscilloscope, easy to use;

2) Have desktop type and systematic type features;

3) Multifunctional voltage output editing mode;

4) Automatic programmable voltage output mode;

5) Bulk data storage function;

6) Support Windows NT, Window 2000, Windows XP, VISTA, Windows 7;

7) Provide secondary development library.

d.Mechanical feature:

1)Operating environment temperature:0~40℃;

2)Operating environment humidity: 0~90% RH;

3)Storage environment temperature:-20℃~70℃;

4)Heat dissipation: natural air cooling.

ii. Oscilloscope Hantek6052BE

  • High performance, 150MS/s real-time sampling, 50MHz Bandwidth,
  • 20 auto measure functions, PASS/FAIL Check, be suitable for technical application.
  • Waveform average, persistence, intensity,invert,addition, subtraction, multiplication, division,X-Y plot.
  • Save waveform in the following: text file, jpg /bmp graphic file, MS excel/word file.
  • Built in FFT function,
  • LabviewVBVCDelphiC++Builder Second Design instance.

Model Hantek6052BE
Bandwidth 50MHz
Channel 2+1(EXT)
Real-time Sample Rate 150MS/s
Record Length 10K-64KB/CH
Rising Time ≤7ns
Time Base Accuracy ±50ppm
Time Base Range 4ns/div-1h/div (Step by1-2-4)
Input Impendence 1MΩ 25pF
Input Sensitivity 10mV/div 5V/div
Vertical Resolution 8Bit
Vertical Position Range 10mV ~ 5V/div @ x1 probe; 100mV ~ 50V/div @ x10 probe;
1V ~ 500V/div @ x100 probe; 10V ~ 5KV/div @ x1000 probe
DC accuracy ±3%
Bandwidth Limit 20MHz
Trigger Type Edge, Alternative
Trigger Source CH1, CH2, EXT, EXT/10
Math +,-,x,÷,FFT, Invert
Cursor Measurement Cross, Trace, Horizontal, Vertical
Auto Measurement Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, +Duty Cycle, -Duty Clycle

iii. Arb. Waveform Generator Hantek1025G

  • Cost-effectiveness; PC USB Function/Arbitrary Waveform Generator.
  • Excellent industrial design-the same anodised aluminium casing as iPad, which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.
  • Plug & Play USB interface, no external power source required; Similar operation interface to benchtop waveform generators, easy to use.
  • It can be used disengaging the computer. Simulation of sensors and Real Word Signals. It will produce the needed arbitrary waveform signals when power on.
  • 200MSa/s sample rate, 12 bits of vertical resolution; 25Mz arbitrary waveform output. (Sine wave up to 75 MHz).
  • One computer can be linked with several HANTEK1025Gto expand Multi-channels.
  • 50 MHz Frequency Counter.
  • Programmable Pattern Generator.
  • Standard USBXI TM interface, easily inserts into USBXI TM housing to make up a combination instrument.

Arbitrary Waveform Output
Wave frequency DC~25MHz
DAC clock 2K~200MHz adjustable
Channels 1CH waveform output
Waveform Length 4KSa
Vertical Resolution 12 bit
Frequency stabilization <30ppm td="">
Amplitude ±3.5V Max.
Output impedance 50 Ω
Output current 50mA Ipeak=50mA
System Bandwidth 25M
Wave distortion -50dBc(1KHz), -40dBc(10KHz)
Frequency Counter
Frequency area DC~50MHz
Input Amplitude 400mVpp~18Vpp
Coupling DC
Frequency precision ±Time Base Error ±1 Count
Input impedance > 100KΩ
Pattern Generator
Digit 12 Bits Pattern Generator and 6Bit digital In
Type LVCMOS
Use condition
Temperature 0~70 centigrade
Humidity 0~95%
Weight 0.3Kg

iv. Logic Analyzer Hantek4032L

  • Pc USB Logic Analyzer LA4032 have a sufficient number of input channels capable of simultaneously observing a lot of information or data flow direction control information, and in some way to capture narrow pulse interference
  • Hantek4032L has delayed the ability to capture the required observation points around the waveform, in a variety of digital information capture function.
  • Hantek4032L have memory capacity, to be able to see the occasional error messages, and the memory can find fault in the source state.
  • Hantek4032L with intuitive and flexible displays to facilitate dynamic analysis, can transform the information, you can use the binary, decimal, hexadecimal or ASCII that information to facilitate the repair process and debug.
  • Hantek4032L triggered in a variety of ways, can be a very long data stream, the analysis of that part of the information to make accurate positioning, which caught right of useful information for software analysis, it can use its tracking function trigger operation procedures. For hardware, trigger function can be detected in the system and that the interference and Burr.

Channel 32
Input Impedance 200K(C=10p)
Input Voltage Range -6V~60V
Voltage Threshold Range -6V~6V
Max. Sample Rate 400MHz
Max. Input Signal Bandwidth 150MHz
Min Time Resolution 2ns
Sample Depth 64M Sample
Memory Depth 2G bits
Compatible Input TTL, LVTTL, CMOS, LVCOMS, ECL, PECL, EIA
Electrostatic Protected Area 15KV
Interface USB Port
Voltage Range 4.5V~5.5V
Power Max. 3.5W
Temperature Range Operation: -10°C~60°C; Storage: -40°C~60°C
Operating System WinXP/2000/Win7
Size&Weight 207(D) x 37(H) x 123(W) mm, about 390g

v. USB Data Logger Hantek365A

  • Convenient Bluetooth function, which can store data in real time on your mobile and computer.
  • Reading resolution: 3 5/6bit (6000 count).
  • AC voltage and current measurement, DC voltage and current measurement, resistance and capacitance testing, short circuit measurement, diode testing, and sensor measurement etc.
  • Real RMS AC voltage and current measurement.
  • USB device and Bluetooth interface.
  • Simple, handy and flexible control software.
  • High cost effectiveness, built in lithium battery (for365C&365D only).
  • Software support: Android (mobile), Windows 2000, Windows 7, Windows XP.

Function Range Accuracy Resolution
DC Voltage 60.00mV ±1% ±1 digit 10uV
600.00mV 100uV
6.00V 1mV
60.00V 10mV
60.00V 100mV
800V 1V
AC Voltage 60.00mV ±1%±3 digit 10uV
600.00mV 100uV
6.00V 1mV
60.00V 10mV
600.0V 100mV
DC Current 60.00mA ±1.5%±1 digit 10uA
600.00mA ±1%±1 digit 100uA
6.000A ±1.5%±3 digit 1mA
10.00A 10mA
AC Current 60.00mA ±1.5%±1 digit 10uA
600.00mA ±1%±1 digit 100uA
6.000A ±1.5%±3 digit 1mA
10.00A 10mA
Resistance 600 ±1%±3 digit 0.1Ω
6.000 K ±1%±1 digit
60.00 K 10Ω
600.0 K 100Ω
6.000 M 1KΩ
60.00 M ±1.5%±3 digit 10KΩ
Capacitance 40.00nF ±1%±1 digit 10pF
400.00nF 100pF
4.000uF 1nF
40.00uF 10pF
400.0uF 100pF
Attention: The smallest capacitance value that can be measured in 5nF
Diode 0V~2.0V


III. Optional Module

I. Oscilloscope Series:

Model Bandwidth Sample Rate
Hantek6022BE 20MS/s 48MSa
Hantek6052BE 50MS/s 150MSa
Hantek6082BE 80MS/s 250MSa
Hantek6102BE 100MS/s 250MSa
Hantek6202BE 200MS/s 250MSa
Hantek6212BE 200MS/s 250MSa

ii. Programmable Power Supply series

PPS1004A

iii. Arb. Waveform Generator series

Hantek1025G

Iv. Logic Analyzer Series

Hantek4032L

V. USB Data Logger Series

Model Hantek365D Hantek365C Hantek365B Hantek365A
True RMS Yes No Yes No
Bluetooth&Battery Yes Yes No No

USBXI-1070B

Referencias específicas