- CONSULTAR
USBXI-1070B
Simultaneous synchronization between modules.
Easy to set up local/wide area network by WIFI/Lan. USB/LAN/WIFI/RGB, and mouse keyboard supported.
The chassis supports the following USB modular products: Oscilloscope, Multimeters, Logic Analyzers, DC Power Supply, Arb. Waveform Generator, Frequency Counter, Field strength meter...
USBXI-1070B
CHASIS PARA EQUIPOS COMPATIBLES CON USBXI
Standard USBXI TM interface, easily inserts into USBXI TM housing to make up a combination instrument.
I. Features & Specifications
- Simultaneous synchronization between modules.
- High-speed USB 2.0, Hot-swappable and auto-detectable characteristic minimizes startup time/effort
- Win XP/ Win 7 Microsoft? Windows? operating system, touch screen, easy to second development.
- Easy to set up local/wide area network by WIFI/Lan.
- USB/LAN/WIFI/RGB, and mouse keyboard supported.
- The chassis supports the following USB modular products: Oscilloscope, Multimeters, Logic Analyzers, DC Power Supply, Arb. Waveform Generator, Frequency Counter, Field strength meter...
- USBXI-1070A: Computer inside with touch screen.
- USBXI-1070B: Computer inside, no screen.
- USBXI-1070C: No computer inside.
II. Optional Module:
Power Supply | Oscilloscope | Arb. Waveform Generator | Logic Analyzer | Data Logger |
Hantek1004A | Hantek6022BE | Hantek1025G | Hantek4032L | Hantek365A |
Hantek6052BE | Hantek365B | |||
Hantek6082BE | Hantek365C | |||
Hantek6102BE | Hantek365D | |||
Hantek6202BE |
III. Standard Modules
Model | USBXI-1070B | USBXI-1070C |
Computer Inside | Yes | No |
Touch Screen | No | No |
WIFI/LAN | Yes | No |
IV. Main Modules Specificaions
i. Programmable Power Supply Hantek1004A
a. Voltage feature
1) Low ripple and low noise;
2) Support high accuracy and dynamic programme output;
3) Fast automated test software programming;
4) Automatic data storage function;
5) Software calibration function and standard instrument board design;
6) Support USB2.0 communication;
7) Support UXI protocol;
8) Input voltage range: DC +12~18V;
9) Be able to arbitrarily work with other instruments.
b. Voltage source specification:
1) Nominal voltage output:
A) Channel 1: DC -5V, 300mA Max;
B) Channel 2: DC +5V, 2000mA Max;
C) Channel 3: DC 0~9V voltage floating output, 2000mA Max;
D) Channel 4: DC 0~9V voltage floating output, 2000mA Max;
2) Setup voltage resolution: DC 10mV;
3) Readback voltage resolution: DC 10mV;
4) Setup voltage accuracy: 0.1%;
5) Readback voltage accuracy: 0.1%;
6) Ripple: 2.5mVp-p.
c. Software:
1) Excellent industrial design, the similar interface to benchtop oscilloscope, easy to use;
2) Have desktop type and systematic type features;
3) Multifunctional voltage output editing mode;
4) Automatic programmable voltage output mode;
5) Bulk data storage function;
6) Support Windows NT, Window 2000, Windows XP, VISTA, Windows 7;
7) Provide secondary development library.
d.Mechanical feature:
1)Operating environment temperature:0~40℃;
2)Operating environment humidity: 0~90% RH;
3)Storage environment temperature:-20℃~70℃;
4)Heat dissipation: natural air cooling.
ii. Oscilloscope Hantek6052BE
- High performance, 150MS/s real-time sampling, 50MHz Bandwidth,
- 20 auto measure functions, PASS/FAIL Check, be suitable for technical application.
- Waveform average, persistence, intensity,invert,addition, subtraction, multiplication, division,X-Y plot.
- Save waveform in the following: text file, jpg /bmp graphic file, MS excel/word file.
- Built in FFT function,
- LabviewVBVCDelphiC++Builder Second Design instance.
Model | Hantek6052BE |
Bandwidth | 50MHz |
Channel | 2+1(EXT) |
Real-time Sample Rate | 150MS/s |
Record Length | 10K-64KB/CH |
Rising Time | ≤7ns |
Time Base Accuracy | ±50ppm |
Time Base Range | 4ns/div-1h/div (Step by1-2-4) |
Input Impendence | 1MΩ 25pF |
Input Sensitivity | 10mV/div ~ 5V/div |
Vertical Resolution | 8Bit |
Vertical Position Range | 10mV ~ 5V/div @ x1 probe; 100mV ~ 50V/div @ x10 probe; 1V ~ 500V/div @ x100 probe; 10V ~ 5KV/div @ x1000 probe |
DC accuracy | ±3% |
Bandwidth Limit | 20MHz |
Trigger Type | Edge, Alternative |
Trigger Source | CH1, CH2, EXT, EXT/10 |
Math | +,-,x,÷,FFT, Invert |
Cursor Measurement | Cross, Trace, Horizontal, Vertical |
Auto Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, +Duty Cycle, -Duty Clycle |
iii. Arb. Waveform Generator Hantek1025G
- Cost-effectiveness; PC USB Function/Arbitrary Waveform Generator.
- Excellent industrial design-the same anodised aluminium casing as iPad, which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.
- Plug & Play USB interface, no external power source required; Similar operation interface to benchtop waveform generators, easy to use.
- It can be used disengaging the computer. Simulation of sensors and Real Word Signals. It will produce the needed arbitrary waveform signals when power on.
- 200MSa/s sample rate, 12 bits of vertical resolution; 25Mz arbitrary waveform output. (Sine wave up to 75 MHz).
- One computer can be linked with several HANTEK1025Gto expand Multi-channels.
- 50 MHz Frequency Counter.
- Programmable Pattern Generator.
- Standard USBXI TM interface, easily inserts into USBXI TM housing to make up a combination instrument.
Arbitrary Waveform Output | |
Wave frequency | DC~25MHz |
DAC clock | 2K~200MHz adjustable |
Channels | 1CH waveform output |
Waveform Length | 4KSa |
Vertical Resolution | 12 bit |
Frequency stabilization | <30ppm td=""> |
Amplitude | ±3.5V Max. |
Output impedance | 50 Ω |
Output current | 50mA Ipeak=50mA |
System Bandwidth | 25M |
Wave distortion | -50dBc(1KHz), -40dBc(10KHz) |
Frequency Counter | |
Frequency area | DC~50MHz |
Input Amplitude | 400mVpp~18Vpp |
Coupling | DC |
Frequency precision | ±Time Base Error ±1 Count |
Input impedance | > 100KΩ |
Pattern Generator | |
Digit | 12 Bits Pattern Generator and 6Bit digital In |
Type | LVCMOS |
Use condition | |
Temperature | 0~70 centigrade |
Humidity | 0~95% |
Weight | 0.3Kg |
iv. Logic Analyzer Hantek4032L
- Pc USB Logic Analyzer LA4032 have a sufficient number of input channels capable of simultaneously observing a lot of information or data flow direction control information, and in some way to capture narrow pulse interference
- Hantek4032L has delayed the ability to capture the required observation points around the waveform, in a variety of digital information capture function.
- Hantek4032L have memory capacity, to be able to see the occasional error messages, and the memory can find fault in the source state.
- Hantek4032L with intuitive and flexible displays to facilitate dynamic analysis, can transform the information, you can use the binary, decimal, hexadecimal or ASCII that information to facilitate the repair process and debug.
- Hantek4032L triggered in a variety of ways, can be a very long data stream, the analysis of that part of the information to make accurate positioning, which caught right of useful information for software analysis, it can use its tracking function trigger operation procedures. For hardware, trigger function can be detected in the system and that the interference and Burr.
Channel | 32 |
Input Impedance | 200K(C=10p) |
Input Voltage Range | -6V~60V |
Voltage Threshold Range | -6V~6V |
Max. Sample Rate | 400MHz |
Max. Input Signal Bandwidth | 150MHz |
Min Time Resolution | 2ns |
Sample Depth | 64M Sample |
Memory Depth | 2G bits |
Compatible Input | TTL, LVTTL, CMOS, LVCOMS, ECL, PECL, EIA |
Electrostatic Protected Area | 15KV |
Interface | USB Port |
Voltage Range | 4.5V~5.5V |
Power | Max. 3.5W |
Temperature Range | Operation: -10°C~60°C; Storage: -40°C~60°C |
Operating System | WinXP/2000/Win7 |
Size&Weight | 207(D) x 37(H) x 123(W) mm, about 390g |
v. USB Data Logger Hantek365A
- Convenient Bluetooth function, which can store data in real time on your mobile and computer.
- Reading resolution: 3 5/6bit (6000 count).
- AC voltage and current measurement, DC voltage and current measurement, resistance and capacitance testing, short circuit measurement, diode testing, and sensor measurement etc.
- Real RMS AC voltage and current measurement.
- USB device and Bluetooth interface.
- Simple, handy and flexible control software.
- High cost effectiveness, built in lithium battery (for365C&365D only).
- Software support: Android (mobile), Windows 2000, Windows 7, Windows XP.
Function | Range | Accuracy | Resolution |
DC Voltage | 60.00mV | ±1% ±1 digit | 10uV |
600.00mV | 100uV | ||
6.00V | 1mV | ||
60.00V | 10mV | ||
60.00V | 100mV | ||
800V | 1V | ||
AC Voltage | 60.00mV | ±1%±3 digit | 10uV |
600.00mV | 100uV | ||
6.00V | 1mV | ||
60.00V | 10mV | ||
600.0V | 100mV | ||
DC Current | 60.00mA | ±1.5%±1 digit | 10uA |
600.00mA | ±1%±1 digit | 100uA | |
6.000A | ±1.5%±3 digit | 1mA | |
10.00A | 10mA | ||
AC Current | 60.00mA | ±1.5%±1 digit | 10uA |
600.00mA | ±1%±1 digit | 100uA | |
6.000A | ±1.5%±3 digit | 1mA | |
10.00A | 10mA | ||
Resistance | 600 | ±1%±3 digit | 0.1Ω |
6.000 K | ±1%±1 digit | 1Ω | |
60.00 K | 10Ω | ||
600.0 K | 100Ω | ||
6.000 M | 1KΩ | ||
60.00 M | ±1.5%±3 digit | 10KΩ | |
Capacitance | 40.00nF | ±1%±1 digit | 10pF |
400.00nF | 100pF | ||
4.000uF | 1nF | ||
40.00uF | 10pF | ||
400.0uF | 100pF | ||
Attention: The smallest capacitance value that can be measured in 5nF | |||
Diode | 0V~2.0V |
III. Optional Module
I. Oscilloscope Series:
Model | Bandwidth | Sample Rate |
Hantek6022BE | 20MS/s | 48MSa |
Hantek6052BE | 50MS/s | 150MSa |
Hantek6082BE | 80MS/s | 250MSa |
Hantek6102BE | 100MS/s | 250MSa |
Hantek6202BE | 200MS/s | 250MSa |
Hantek6212BE | 200MS/s | 250MSa |
ii. Programmable Power Supply series
PPS1004A
iii. Arb. Waveform Generator series
Hantek1025G
Iv. Logic Analyzer Series
Hantek4032L
V. USB Data Logger Series
Model | Hantek365D | Hantek365C | Hantek365B | Hantek365A |
True RMS | Yes | No | Yes | No |
Bluetooth&Battery | Yes | Yes | No | No |